Explosion parameters of combustible dust
Analysis package to determine the ignitability and explosibility parameters of combustible dust samples after combustibility has been confirmed with the go/no-go screening test.
The following are examples of explosibility tests that can be included in the package:
MIT – Minimum ignition temperature of dust layers and dust clouds (ISO/IEC 80079-20-2)
MIE – Minimum ignition energy (EN 13821)
LOC – Limiting oxygen concentration (EN 14034-4+A1)
Resistivity (ISO/IEC 80079-20-2)
LEL – Lower explosive limit (EN 14034-3+A1)
Maximum explosion pressure (pmax), pressure increase speed ((dp/dt)max), and explosion constant (KSt) according to EN 14034-1+A1 and EN 14034-2+A1
Classification of the explosive group
An accredited test report will be provided.
- Suitable sample matrices
- Fine powders
- Required sample quantity
- ≥ 3 kg
- Available quality systems
- Accredited test method
- Method expert
Questions? We're happy to help.
Questions? We're happy to help.
Business hours: Mon–Fri 9 AM – 5 PM Finnish time (EST/EEST)
Other tests we offer
Dust explosibility screening (go/no go test)
IMO 2010 FTP Code Part 2 – Smoke and toxicity test
Diesel exhaust fluid (e.g. AdBlue) testing according to ISO 22241
Color fastness of dyed paper and board in contact with food
XRR of thin films or coatings
Horizontal flame propagation according to UN/ECE Regulation No. 118, Annex 6
Linear thermal expansion of solids with a rod dilatometer
Melting behavior of fusible materials according to UN/ECE Regulation No. 118, Annex 7
Peroxide value of food and feed
IMO 2010 FTPC Part 8 – Test for upholstered furniture