Concora medium test (CMT30) for flutings
This method is used to determine the flat crush resistance of a corrugating medium after being fluted to A-flute geometry with a laboratory fluting device.
The Concora corrugating medium test can be used for any corrugating medium that is intended to be used on a corrugated board.
- Suitable sample matrices
- Fluting
- Typical turnaround time
- 3 weeks after receiving the samples
- Available quality systems
- Accredited testing laboratory
- Device types
- Method expert
Price
Typical price (Excl. VAT):
136 €
We also charge a 97 € service fee per order.
Large batches of samples are eligible for discounts.
Questions? We're happy to help.
Questions? We're happy to help.
Business hours: Mon–Fri 9 AM – 5 PM Finnish time (EST/EEST)
Other tests we offer
Horizontal impact test for corrugated cardboard
ISO 2244
Horizontal impact testing by the ISO 2244 standard is used to determine the effect of a vertical impact on the horizontal edge of finished and filled cardboard containers. In the test, the packaging is placed on a carriage that is rolled against an impact apparatus. Testing can include a single test or a series of impact tests to evaluate the packaging's ability to perform in environments with a horizontal impact hazard.
272 €
Read moreFolding endurance of paper and board
This test is used to determine the folding endurance of paper or board using the Köhler-Molin, Lhomargy, MIT, and Schopper testers.
During the test, a narrow strip of paper is folded forwards and backward in a standardized manner, so that it is subjected to longitudinal stress until it breaks.
120 €
Read moreBending stiffness of corrugated cardboard
Bending stiffness testing is performed to evaluate cardboard's stiffness by measuring the resistance to bending with 4-point loading.
The results express the bending stiffness of the material in the machine direction and the cross direction.
95 €
Read moreOxygen transmission rate (OTR) of packages
ASTM F1307
This test is designed to measure the oxygen transmission rate of finished packages, including cups, bottles, trays, and containers. Two replica measurements are included in the displayed price. Temperature can be adjusted from 15 to 55 °C, and relative humidity can be either 0% or between 5 and 90% RH. This test is not suitable for films. Please see the oxygen transmission rate (OTR) of films and sheeting if you need testing for film samples. Please specify the sample dimensions and testing conditions upon ordering.
792 €
Read morePhthalates analysis package (REACH)
Phthalates are a group of chemicals widely used as plasticizers, which make plastics more flexible and durable. They have also been used as additives in products such as cosmetics and personal care items. Several phthalates have been identified as endocrine-disrupting agents or as chemicals toxic to reproduction. Exposure to phthalates can occur through: Oral exposure Food: Exposure occurs via migration from food packaging., Children's toys: Children often put toys in their mouths.., Inhalation: Breathing in dust from vinyl flooring or fragrances (like perfumes) can cause exposure to phthalates via inhalation., Skin contact: Phthalates present in cosmetics, lotions, and soaps can be absorbed through the skin.. For other listed matrices apart from cosmetics, the analysis package covers the following substances included in the REACH Authorization List: Substance Abbreviation CAS number Diisobutyl phthalate DIBP 84-69-5 Dibutyl phthalate DBP 84-74-2 Benzyl butyl phthalate BBP 85-68-7 Bis(2-ethylhexyl) phthalate DEHP 117-81-7 Di(n-octyl) phthalate DNOP 117-84-0 Diisononyl phthalate DINP 68515-48-0 Diisodecyl phthalate DIDP 26761-40-0 Products that contain restricted phthalates in concentrations higher than 0.1% may be removed from the market. The analysis package for cosmetic products contains the following phthalates: Substance Abbreviation CAS number Bis(2-ethylhexyl) phthalate DEHP 117-81-7 Benzyl butyl phthalate BBP 85-68-7 Dibutyl phthalate DBP 84-74-2 Diisononyl phthalate DINP 68515-48-0 Di(n-octyl) phthalate DNOP 117-84-0 Diisodecyl phthalate DIDP 26761-40-0 All the above-mentioned substances are prohibited in cosmetic products (Annex II of Regulation (EC) No 1223/2009).
241 €
Read moreDioxins and furans (PCDD/F) in plastic, paper, and rubber
Analysis for quantifying dioxins and furans (PCDD/F) in various packaging materials (e.g. food and cosmetics packaging) and their raw materials, including plastics, paper, and rubber. Dioxins and furans are a family of chlorine-containing chemicals considered bioaccumulating, persistent organic pollutants (POPs) that can be toxic even at low doses. While regulatory limits apply mainly to food and feed, packaging materials can be a source of indirect exposure to dioxins and furans. Recycled materials tend to pose relatively high risks, depending on the quality of the raw material and the effectiveness of the decontamination process. The following substances are included in the analysis: Dibenzo-p-dioxins (PCDDs) Polychlorinated dibenzofurans (PCDFs) 2,3,7,8-TCDD. 2,3,7,8-TCDF. 1,2,3,7,8-PeCDD. 1,2,3,7,8-PeCDF. 1,2,3,4,7,8-HxCDD. 2,3,4,7,8-PeCDF. 1,2,3,6,7,8-HxCDD. 1,2,3,4,7,8-HxCDF. 1,2,3,7,8,9-HxCDD. 1,2,3,6,7,8-HxCDF. 1,2,3,4,6,7,8-HpCDD. 1,2,3,7,8,9-HxCDF. OCDD. 2,3,4,6,7,8-HxCDF. 1,2,3,4,6,7,8-HpCDF. 1,2,3,4,7,8,9-HpCDF. OCDF. Testing is often performed for the following reasons: Analyzing recycled PE, PP, and LDPE intended for cosmetics packaging according to CosPaTox guidelines., Analyzing paper and board bleached with elementary chlorine according to the requirements of TemaNord 2008:515 guidelines..
538 €
Read moreTotal organic fluorine (TOF) content in challenging sample materials (chemicals, oils, etc.)
ASTM D7359
Determination of the total organic fluorine (TOF) content in combustible materials by combustion ion chromatography (CIC). TOF analysis gives information about the total amount of organic fluorinated compounds. It can also be used to evaluate the presence of per- and polyfluoroalkyl substances (PFAS) in the material, even though individual PFAS compounds can't be analyzed with this method. The analysis is suitable for many different materials. Please describe the sample in detail when requesting an offer to help us prepare a quote quickly.
350–600 €
Read moreWater vapor transmission rate (WVTR) of ultra-high barrier films and sheetings
Determination of the water vapor transmission rate (WVTR) of ultra-high barrier materials. The method can also be used to test moderate barrier materials at high-temperature conditions. Please disclose the desired temperature (from 10 to 85 °C) and the desired relative humidity (from 60% to 100%) when placing the order. This measurement is applicable for films and sheeting materials with WVTR values between 1x10-6 and 10 g/m2/day. If you wish to test finished packaging instead, check out the WVTR measurement for packages. The price of the test consists of a flat rate cost per sample plus one day measurement time. Please contact our experts for an offer.
570 €
Read moreOxygen transmission rate (OTR) of plastic films and sheeting
ASTM D3985, ASTM F1927, ASTM F2622-08, …
Determination of the oxygen transmission rate of plastic films and sheet-like materials. The test is performed on two parallel samples simultaneously. Measurement conditions (temperature and relative humidity) can be chosen according to the intended use of the material. Oxygen permeability is typically measured at 23 °C and 0% relative humidity as per standard ASTM D3985. In moist conditions, for example at 38 °C and 90% relative humidity, standard ASTM F1927 is used. Please disclose the desired temperature (from 10 °C to 38 °C) and relative humidity (either 0% or from 20% to 90%) upon ordering. This measurement is suitable for plastic films with OTR values between 0.05 to 20 000 cm3/(m2 * day).
420 €
Read moreRecyclability of paper and board - Aticelca 501:2023
Recyclability testing of paper and cardboard packaging according to the Aticelca 501:2023 method. The method is based on the Italian UNI 11743: 2019 standard. The following properties are evaluated: Disintegration behavior and recyclable content, Impurity content (e.g., plastic, coatings, adhesives), Visual appearance. Based on the results, the material is given a recyclability classification of A+, A, B, or C. A+ indicates a highly recyclable material, while C indicates a product with poor recyclability. The material can also be classified as non-recyclable with paper.
1,143 €
Read more”Excellent service. Measurlabs chose analysis methods for our demanding sample, interpreted the results and delivered a thorough analysis report. We would buy again.”
Antti Tullila, Senior Development Manager, Aidian
Ask for an offer
Fill in the form, and we'll reply in one business day.