Total organic carbon (TOC)
Determination of total organic carbon (TOC) content of water samples.
The results of the analysis will be reported in mg/l.
- Suitable sample matrices
- Water
- Required sample quantity
- 25 ml
- Typical turnaround time
- 2 weeks after receiving the samples
- Detection limit
- 0.5 mg/l
- Available quality systems
- Accredited test method
- Device types
- Method expert
Price
Typical price (Excl. VAT):
50 €
We also charge a 97 € service fee per order.
Large batches of samples are eligible for discounts.
Questions? We're happy to help.
Questions? We're happy to help.
Business hours: Mon–Fri 9 AM – 5 PM Finnish time (EST/EEST)
Other tests we offer
ICP-MS measurement (wide) for water samples
EN ISO 17294-2, EN ISO 178 52, EN 16192, …
Determination of Be, Ba, Co, Al, Mg, Cu, Li, Mn, Ag, Sn, Ti, V, Zn, Tl, B, Hg, Mo, Fe, Ca, K, U, P, Cd, Na, Cr, Ni, Pb, Sb, As, and Se in water samples with ICP-MS-technique. The sample is homogenized and acidified (HNO3), after which the analysis is performed from the liquid phase. The displayed price applies to natural waters. If the sample contains a lot of solids or the matrix is significantly different from natural water (for example, wastewater and industrial waters), additional steps may be needed, and this will be reflected in the price. The concentration of each element is reported in µg/l.
95 €
Read moreHeavy metals quantification in water sample by ICP-MS
EN ISO 17294-2, EN ISO 178 52, EN 16192, …
Determination of total metal concentrations in a water sample using ICP-MS technology. The analysis package includes the elements Sb, As, Hg, Cd, Co, Cr, Cu, Pb, Ni, Zn, and V. The concentration of each element is expressed in µg/l. The method is suitable for various sample types, from natural waters to wastewater. However, for highly contaminated samples, the method's reporting limits may increase. More elements can be added to the analysis package upon request. We will be happy to prepare a customized offer for you.
73 €
Read moreUltrapure water testing
We have various testing services available for ultrapure water. Pricing depends on the selected analyses and the number of samples. Please contact Measurlabs to get an offer. Note that we will provide suitable shipping containers based on the analyses that are ordered. Trace elements by ICP-MS For the determination of elemental impurities, we offer a basic 36-element and an extended 67-element package. The basic package includes the following 36 elements: Li, Be, B, Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Sr, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Ba, Ta, W, Pt, Au, Tl, Pb, and Bi. The extended analysis includes the following elements in addition to the basic package: Ce, Cs, Dy, Er, Eu, Gd, Hf, Ho, In, Ir, La, Lu, Hg, Nd, Os, Pd, Pr, Re, Rh, Rb, Ru, Sm, Sc, Se, Te, Tb, Th, Tm, U, Yb, and Y. Reporting limits depend on the element and sample matrix, but typically vary between 0.001 ppb and 0.6 ppb. For this analysis, samples must be delivered in Teflon containers. Hardness Hardness value can be calculated based on the ICP-MS results. Silicon and silica (Si, SiO2) Our service catalog includes the determination of total, dissolved, and colloidal silica (SiO2). Total silicon is analyzed using the ICP-OES technique, and dissolved silicon by UV-VIS (molybdenum heteropoly blue method). Colloidal silica is calculated as the difference between total silica and dissolved silica. Total organic and inorganic carbon (TOC and TIC) We offer TOC determination for ultrapure water samples with a 5 ppb quantification limit. For this analysis, samples must be delivered in certified 40 ml TOC vials. Total inorganic carbon (TIC) analysis can also be performed using a TOC analyzer. Anions by ion chromatography (IC) For anions, we have a basic package and a separate package for organic anions. The basic package includes the following anions: bromide(Br−), chloride (Cl−), fluoride (F−), nitrate (NO3−), nitrite (NO2−), phosphate (PO43−), and sulfate (SO42−). Analysis of organic anions includes: acetate, formate, glycolate, propionate, and butyrate. Reporting limits depend on the anion and sample matrix, but typically vary between 0.02 and 1 ppb for basic anions and are around 25 ppb for organic anions. For this analysis, samples must be delivered in HDPE bottles. Cations by ion chromatography (IC) The analysis package for cations includes the determination of the following cations: ammonium (NH4+), calcium (Ca2+), lithium (Li+), magnesium (Mg2+), potassium (K+), and sodium (Na+). Reporting limits typically vary between 2 ppb and 5 ppb. Samples must be delivered in HDPE bottles. PFAS compounds (24 compounds) Analysis includes PFOS, PFOA, PFNA, PFHxS, and 20 other selected PFAS compounds. The complete list of compounds can be provided upon request. The reporting limit of the results is typically 1 ng/L. The sample must be delivered in a plastic PFAS-free bottle, preferably made from HDPE.
Read more
Metal screening by ICP-SFMS (semi-quantitative)
This metal screening analysis includes the semi-quantitative determination of 70 elements. The method can be used, for example, to determine the background concentrations of metals in environmental samples or to study the elemental distribution of unknown samples. Screening is also often performed to assess which metals should be analyzed by a quantitative method. The measurement is performed using a high-resolution ICP-MS technique (ICP-SFMS), which can identify very low elemental concentrations. A semi-quantitative determination of the following elements is included: Ag, Al, As, Au, B, Ba, Be, Bi, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Dy, Er, Eu, Fe, Ga, Gd, Ge, Hf, Hg, Ho, I, Ir, K, La, Lu, Mg, Mn, Mo, Na, Nb, Nd, Ni, Os, P, Pb, Pd, Pr, Pt, Rb, Re, Rh, Ru, S, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Te, Th, Ti, Tl, Tm, U, V, W, Y, Yb, Zn and Zr. However, please note that some elements may not be determinable due to matrix interference. During this semi-quantitative analysis, the instrument is calibrated for about 30 elements and the rest of the analytes are quantified using sensitivity factors for calibrated elements with similar mass and first ionization potential considering isotope abundances. Quantitative analysis is also available at an additional price. During this analysis, all elements are calibrated (excluding halogens and Os). Please ask for an offer for this service.
753 €
Read moreICP-OES metal quantification - soil, sludge, and sediment (wide analysis package)
EPA 200.7, EPA 3050, EPA 6010, …
ICP-OES measurement package for soil, sludge, or sediment samples. Pre-treatment of the sample with aqua regia decomposition is included in the price. The following elements are quantified using the ICP-OES technique: Ag, As, Ba, Be, Cd, Co, Cr, Cu, Fe, Hg, Li, Mn, Mo, Ni, Pb, Sb, Sn, Sr, Tl, V, and Zn. The concentrations are expressed in mg/kg d.m. The analysis is also available with an express turnaround time. Ask our experts for more information. More specific packages, such as heavy metals or nutrients, can also be provided for soil, sediment, or sludge samples.
95 €
Read moreCHNOS analysis of organic materials
Determination of carbon, hydrogen, nitrogen, sulfur, and oxygen content of an organic sample. CHNS analysis (”LECO analysis”) is performed using a flash combustion method, where the sample is combusted under 25 kPa of O2 at an elevated temperature (1000 °C), followed by gas chromatography separation and detection using a thermal conductivity detector. Oxygen is analyzed by reduction on granulated carbon at 1480 °C, utilizing high-temperature thermal decomposition and conversion of oxygen into carbon monoxide before gas chromatography separation and detection with a thermal conductivity detector. The sample can be either solid or liquid, but water in the sample affects the results. In the case of aqueous samples, it is possible to dry the sample before analysis. The displayed price by includes the full CHNOS package with two parallel measurements and applies to conventional organic samples. The results are reported as wt-% of the initial sample. The ash, drying and dry loss measurements will increase the minimum required sample material need to 300 mg. The analysis gives the total carbon, hydrogen, nitrogen, sulfur, and oxygen content of the material, but it does not identify any chemical structures. The measurement can be combined with other methods, such as GC-MS, 1H, and 13C NMR, to perform substance structure identification. Analysis can be split into the following packages: CHN, O, and S.
190 €
Read moreTotal fluorine content in plastic
EN 15408
Determination of total fluorine (F) content in plastic according to the EN 15408 mod. method. The fluorine content of the sample is obtained using oxygen bomb combustion treatment followed by ion chromatography (IC). Possible sample preparation, such as grinding into smaller particles, is available at an extra cost. This method can also be used to determine the total content of S, Cl, and Br. The results will be reported in mg/kg.
248 €
Read moreNanoparticle analysis according to REACH
The following analyses are included in this nanoparticle analysis package, intended to characterize nanoforms according to the REACH Regulation. Particle size distribution and aspect ratios by SEM-EDX Preparation with isopropanol, Sample dispersion on a slide, with centrifugation, SEM analysis and particle count by image analysis, Nanoparticle detection and classification according to the 2022 EC recommendation on the definition of nanomaterial, Reporting of PSD parameters for ~300 particles, including the following: PSD diagram, accumulated and individual., Feret min (min, d10, d25, d50, d75, d90, d95, max), Feret max (min, d10, d25, d50, d75, d90, d95, max), Equivalent circular diameter (min, d10, d25, d50, d75, d90, d95, max), Aspect ratio (calculated based on individual Feret min and Feret max measurements), Number based nano-fraction (%).. Crystal phase analysis by XRD/Rietveld method Sample preparation: drying, grinding, X-ray preparation, XRD analysis over an angular range extending from 10° to 90°, Identification of the crystalline phases present in the sample, Semi-quantitative analysis of phase distribution, using the Rietveld method, Interpretation of diffractograms. Chemical composition/purity by ICP-AES and CHNS analysis ICP-AES quantification of inorganic and metallic elements: Ag, Al, As, B, Ba, Be, Bi, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, S, Se, Sb, Si, Sn, Sr, V, Zn, Ti, and Tl, Determination of C, H, N, and S with an elemental analyzer. Volume-specific surface area (VSSA) and VSSA diameter calculations (optional) BET specific surface area measurement of powder by nitrogen adsorption, True (skeletal) density measurement by He pycnometry, excluding intergranular and intragranular porosity, Both analyses include sample preparation. You can request a quote for the analysis using the form below. Please note that the OECD 125 guideline does not apply to this analysis.
2,200–2,968 €
Read moreAnions in soil, sludge, sediment and water samples (ISO 10304-1, EN 16192)
EN 16192, ISO 10304-1
Determination of bromide, fluoride, chloride, nitrate, nitrite, and sulfate (Br-, F-, Cl-, NO2-, NO3- ja SO42-) in soil, sludge, sediment, and water samples with ion chromatography. For soil, sludge, and sediment, the analysis is carried out after a water extraction. Ask about the price for other solid matrices and more challenging aqueous matrices. Please store the samples in refrigerated conditions and in gas-sealed containers.
113 €
Read moreChemisorption
Volumetric (static) or dynamic (pulse) chemisorption analysis by CO or H2. The method is mainly used to determine catalyst activity and active sites. When coupled with TPX (temperature programmed experiments, TPO, TPR, TPD), this method can give information about adsorbed species and surface species. Chemisorption can also be conducted with other reactive gases, please contact us for more information.
349–1,890 €
Read more”Measurlabs was extremely helpful in all our requests during the preceding months. When we had high time pressure to get analytical support, they handled all our requests swiftly. Whenever we have future analytical needs we will remember their excellent service.”
Erich Seger, H.B. Fuller Deutschland GmbH
Ask for an offer
Fill in the form, and we'll reply in one business day.