Monoterpenes in liquid biomass samples
Quantification of monoterpenes and related terpene compounds in liquid biomass samples by an in-house GC-MS method. The typical LOQ is approximately 10 mg/kg per compound, depending on the exact sample matrix. The list of quantified substances and their estimated LOQs are provided in the Technical Annex.
The displayed price applies to small sample sets; larger batches and recurring orders are eligible for volume discounts.
- Suitable sample matrices
- Liquid biorefinery samples, such as methanol, black liquor and condensates
- Required sample quantity
- 5 mL
- Typical turnaround time
- 4 weeks after receiving the samples
- Detection limit
- 10 mg/kg
- Available quality systems
- Accredited testing laboratory
- Device types
- GC-MS
- Method expert
Price
Typical price (Excl. VAT):
500 €per sample
We also charge a 97 € service fee per order.
Large batches of samples are eligible for discounts.
Questions? We're happy to help.
Questions? We're happy to help.
Business hours: Mon–Fri 9 AM – 5 PM Finnish time (EET/EEST)
Other tests we offer
Semi-quantitative elemental screening with ICP-SFMS
This metal screening analysis includes the semi-quantitative determination of 70 elements. The method can be used, for example, to determine the background concentrations of metals in environmental samples or to study the elemental distribution of unknown samples. Screening is also often performed to assess which metals should be analyzed by a quantitative method. The measurement is performed using a high-resolution ICP-MS technique (ICP-SFMS), which can identify very low elemental concentrations. A semi-quantitative determination of the following elements is included: Ag, Al, As, Au, B, Ba, Be, Bi, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Dy, Er, Eu, Fe, Ga, Gd, Ge, Hf, Hg, Ho, I, Ir, K, La, Lu, Mg, Mn, Mo, Na, Nb, Nd, Ni, Os, P, Pb, Pd, Pr, Pt, Rb, Re, Rh, Ru, S, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Te, Th, Ti, Tl, Tm, U, V, W, Y, Yb, Zn and Zr. However, please note that some elements may not be determinable due to matrix interference. During this semi-quantitative analysis, the instrument is calibrated for about 30 elements. The rest of the analytes are quantified using sensitivity factors for calibrated elements with similar mass and first ionization potential, considering isotope abundances. Quantitative analysis is also available at an additional price. During this analysis, all elements are calibrated (excluding halogens and Os). Please ask for an offer for this service.
791 €
Read moreFiber furnish analysis with the Herzberg staining test
ISO 9184-3
The Herzberg staining test by the ISO 9184-3 standard is used to determine the main fiber content of paper and board. In the test, a saturated solution of zinc chloride, iodine, and potassium iodide is used to color the paper. The solution affects fibers differently and enables the qualitative and quantitative analysis of mechanical, rag, chemical, and semi-chemical pulps, regenerated cellulose fibers, and synthetic fibers in paper and board.
Read more
CHNOS stable isotope analysis in solid samples
Stable isotope analysis of the elements in solid samples with isotope-ratio mass spectrometry (IRMS). Measurable isotopes given below: Isotope ratio Description δ13C Ratio of 13C to 12C δ2H (δD) Ratio of 2H to 1H (deuterium to protium) δ15N Ratio of 15N to 14N δ18O Ratio of 18O to 16O δ34S Ratio of 34S to 32S The results are reported as per mille (‰) deviations of the ratio of the heavy and light isotopes for the given element in comparison to a standard reference material. We have more than 30 IAEA, USGS, and in-house isotopic standards available to accommodate a wide range of expected ratios. Samples should be non-hazardous, dry, thermally decomposable and homogenous. The minimum sample count is 50 per batch. The price and turnaround time displayed apply to conventional sample matrices. The analysis is suitable for a wide range of materials, including, but not limited to, soils, plants, and insect tissue. All of our stable isotope analyses are conducted by ISO 17025-accredited facilities.
90 €
Read moreFluorine content of challenging sample materials (chemicals, oils, etc.)
ASTM D7359
Determination of the total organic fluorine (TOF) content in combustible materials using combustion ion chromatography (CIC). By default, TOF is analyzed as total fluorine (TF). If required, total inorganic fluorine (TIF) can be measured as well, and TOF calculated as the difference between TF and TIF. TOF analysis gives information about the total amount of organic fluorinated compounds. It can also be used to evaluate the presence of per- and polyfluoroalkyl substances (PFAS) in the material, even though individual PFAS compounds can't be analyzed with this method. The analysis is suitable for many different materials. Please describe the sample in detail when requesting an offer to help us prepare a quote quickly.
368–630 €
Read moreFree monomeric sugars in biomass-based solutions
Determination of free monomeric sugars in liquid biomass samples by in-house HPLC method with refractive index detection. The following sugars are quantified: glucose, mannose, galactose, xylose, and arabinose. Results are reported in mg/ml. Organic acids (formic acid, acetic acid, levulinic acid) and furans (furfural, 5-HMF, 5-MF) can be included with an additional price. Please indicate which parameters you would like reported when requesting an offer. Solid particles are removed by filtration prior to analysis, where needed. The lower displayed price applies to free sugar analysis only, while the higher one also includes organic acids.
348 €
Read moreExtractives content in biomass
ISO 14453, NREL/TP 510-42619, TAPPI T204
Gravimetric determination of extractives content in solid biomass. Non-volatile extractives soluble in organic solvents (acetone, ethanol, benzene) can be quantified. Other solvents can also be used upon request. The analysis can be performed according to standard TAPPI T204 (acetone or ethanol/benzene) using Soxhlet extraction. The extractives content is reported as w-%. NREL/TP 510-42619 method (ASE extraction) is available at a higher price.
195–350 €
Read moreCharacterization of polymers by py-GC-MS
Pyrolysis gas chromatography-mass spectrometry (py-GC-MS) analysis to determine the identity of an unknown polymer sample. During the measurement, the sample is instantaneously heated in an inert atmosphere or vacuum. This causes the sample to decompose into smaller molecular fragments, which are then analyzed with GC-MS. Different types of polymers can be identified by their unique decomposition products. This includes, but is not limited to: PE, PP, PS, ABS, PMMA, PET, PC, PVC, polyamides, natural & synthetic rubbers, and more. The price includes the basic preparation and qualitative analysis of the sample. More extensive sample preparation and quantitative analyses are subject to additional costs.
542–742 €
Read moreBlack liquor analysis package
SCAN N 38
Analysis package for black liquor and pulp mill process liquids, covering the following parameters: Parameter Method Dry matter content SCAN-N 22 Carbonate SCAN-N 32 Dissolved calcium (Ca) In-house Sodium (Na) SCAN-N 38 Results are reported in mg/kg dry basis or mg/L. Please note that a sample destruction fee will be applied to smelly or otherwise hazardous samples. The displayed price applies to small sample sets; large batches are eligible for discounts.
755 €
Read moreSynchrotron XRD measurement - Quantitative analysis
This analysis provides quantitative information about the crystalline and amorphous phases within your sample using high-resolution synchrotron X-ray diffraction (XRD). A standard analysis includes: Quantification of crystalline phases as weight percentages, Quantification of the total amorphous content, High-resolution powder diffraction data and the resulting diffractogram, A comprehensive test report detailing the findings. For more advanced needs, we also offer total scattering/pair distribution function (PDF) analysis to reveal the local atomic structure in amorphous or nano-structured materials. Do not hesitate to ask for a quote.
179–545 €
Read moreAsh content analysis according to ASTM D482 or EN ISO 6245
ASTM D482, EN ISO 6245
This ash content test is conducted according to ASTM D482 or EN ISO 6245, and is typically used for pyrolysis oil, fuels, crude oils, lubricating oils, waxes, and related petroleum matrices where ash-forming material is considered an undesirable impurity. In the test, the sample is ignited under controlled laboratory conditions at 775 °C, and the remaining ash residue is determined gravimetrically. Results are reported as numerical values in w%, with a typical quantification limit of 0.001 w%. Both ASTM D482 and EN ISO 6245 are generally applicable in the approximate ash range of 0.001 to 0.180 w% for petroleum products that do not contain intentional ash-forming additives; products with such additives may require a different method. Please note that the displayed price applies to small sample sets, while larger batches and recurring orders are eligible for volume-based discounts.
68 €
Read more”Being able to source practically all the required tests through Measurlabs makes my work considerably easier, as I do not have to coordinate testing across multiple laboratories. ”
Farnaz Shokraneh, Head of Quality Assurance and Quality Control, CurifyLabs
Ask for an offer
Fill in the form, and we'll reply in one business day.
Have questions or need help? Email us at info@measurlabs.com or call our sales team.