ICP-MS metal screening of solvent samples

The ICP-MS technique provides information on the concentrations of metals in a sample. The measurement includes the following elements: Na, Mg, K, Ca, Li, Be, B, Al, Si, P, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, Zr, Nb, Mo, Ag, Cd, In, Sn, Sb, Te, Cs, Ba, Hf, Hg, Tl, Pb, Bi, U. In the results, the elemental concentrations are expressed in units mg/kg.

Suitable sample matrices
Organic solvent samples
Minimum sample amount
50 ml
Typical turnaround time
3 weeks after receiving the samples
Detection limit
Hf, Hg, Pb, U: 0.0001 mg/kg Ga, In, Rb: 0.0005 mg/kg Ag, Cd, Co, Cs, Mn, Mo, Nb, Sb, Sn, Ti, Tl: 0.001 mg/kg Te, V: 0.005 mg/kg As, B, Ba, Be, Bi, Cr, Cu, Fe, Li, Ni, Se, Sr, Zr: 0.01 mg/kg Zn: 0.05 mg/kg Al, Mg: 0.1 mg/kg Si, P: 0.5 mg/kg Ca, K, Na: 1 mg/kg
Quality system
Accredited testing laboratory
Device types
Method expert
Mirva Hirvi
Price (VAT 0)
First sample: 442 €
Additional samples: 328 € per sample

Questions? We're happy to help.