Amino acid identification in water
Determination of amino acids from waste water. The analysis includes the determination of the following amino acids:
Alanine
Arginine
Asparagine
Aspartate
Citrulline
Cystine/Cysteine*
Glutamate
Glutamine
Glycine
Histidine
Hydroxyproline
Isoleucine
Leucine
Lysine
Methionine
Ornithine
Phenylalanine
Proline
Serine
Taurine
Threonine
Tryptophane
Tyrosine
Valine
- Suitable sample matrices
- Water
- Required sample quantity
- 1 ml
- Typical turnaround time
- 3 weeks after receiving the samples
- Detection limit
- < 0.03 mmol/l
- Available quality systems
- Measurlabs validated method
- Method expert
Price
Typical price (Excl. VAT):
340 €
We also charge a 97 € service fee per order.
Large batches of samples are eligible for discounts.
Questions? We're happy to help.
Questions? We're happy to help.
Business hours: Mon–Fri 9 AM – 5 PM Finnish time (EST/EEST)
Other tests we offer
Metal screening by ICP-SFMS (semi-quantitative)
This metal screening analysis includes the semi-quantitative determination of 70 elements. The method can be used, for example, to determine the background concentrations of metals in environmental samples or to study the elemental distribution of unknown samples. Screening is also often performed to assess which metals should be analyzed by a quantitative method. The measurement is performed using a high-resolution ICP-MS technique (ICP-SFMS), which can identify very low elemental concentrations. A semi-quantitative determination of the following elements is included: Ag, Al, As, Au, B, Ba, Be, Bi, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Dy, Er, Eu, Fe, Ga, Gd, Ge, Hf, Hg, Ho, I, Ir, K, La, Lu, Mg, Mn, Mo, Na, Nb, Nd, Ni, Os, P, Pb, Pd, Pr, Pt, Rb, Re, Rh, Ru, S, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Te, Th, Ti, Tl, Tm, U, V, W, Y, Yb, Zn and Zr. However, please note that some elements may not be determinable due to matrix interference. During this semi-quantitative analysis, the instrument is calibrated for about 30 elements and the rest of the analytes are quantified using sensitivity factors for calibrated elements with similar mass and first ionization potential considering isotope abundances. Quantitative analysis is also available at an additional price. During this analysis, all elements are calibrated (excluding halogens and Os). Please ask for an offer for this service.
753 €
Read moreICP-MS measurement (wide) for water samples
EN ISO 17294-2, EN ISO 178 52, EN 16192, …
Determination of Be, Ba, Co, Al, Mg, Cu, Li, Mn, Ag, Sn, Ti, V, Zn, Tl, B, Hg, Mo, Fe, Ca, K, U, P, Cd, Na, Cr, Ni, Pb, Sb, As, and Se in water samples with ICP-MS-technique. The sample is homogenized and acidified (HNO3), after which the analysis is performed from the liquid phase. The analysis is suitable for natural waters. If the sample contains a lot of solids or the matrix is significantly different from natural water (for example waste and industrial waters), please contact our testing expert and ask for an offer. The concentration of each element is reported in µg/l.
95 €
Read moreCharacterization of polymers by py-GC-MS
Pyrolysis gas chromatography-mass spectrometry (py-GC-MS) analysis to determine the identity of an unknown polymer sample. During the measurement, the sample is instantaneously heated in an inert atmosphere or vacuum. This causes the sample to decompose into smaller molecular fragments which are then analyzed with GC-MS. Different types of polymers can be identified by their unique decomposition products. This includes, but is not limited to: PE, PP, PS, ABS, PMMA, PET, PC, PVC, polyamides, natural & synthetic rubbers, and more. The price includes the basic preparation and analysis of the sample. More extensive sample preparation is subject to additional costs.
542 €
Read morePolycyclic aromatic hydrocarbon (PAH) analysis of solid samples
GC-MS analysis of 16 PAH compounds, which are listed as high-priority pollutants by the U.S. Environmental Protection Agency (EPA). The analyzed PAH compounds are: naphthalene [CAS: 91-20-3], acenaphthylene [CAS: 208-96-8], acenaphthene [CAS: 83-32-9], fluorene [CAS: 86-73-7], phenanthrene [CAS: 85-01-8], anthracene [CAS: 120-12-7], fluoranthene [CAS: 206-44-0], pyrene [CAS: 129-00-0], benz(a)anthracene [CAS: 56-55-3], chrysene [CAS: 218-01-9], benzo(b)fluoranthene [CAS: 205-99-2], benzo(k)fluoranthene [CAS: 207-08-9], benzo (a) pyrene [CAS: 50-32-8], dibenzo(ah)anthracene [CAS: 53-70-3], benzo (ghi) perylene [CAS: 191-24-2], indeno (123cd) pyrene [CAS: 193-39-5].
166 €
Read moreTOP assay (PFAS precursors)
Total oxidizable precursors (TOP) assay analysis can be used when estimating the presence of PFAS precursors and intermediates by oxidizing them into stable end-products. The analysis can be combined with traditional PFAS analysis methods to obtain additional information. The analysis is suitable for different matrices, for example, water and fire-fighting foams. Contact the method expert for more information.
250–450 €
Read moreHeavy metals quantification in water sample by ICP-MS
EN ISO 17294-2, EN ISO 178 52, EN 16192, …
Determination of Sb, As, Hg, Cd, Co, Cr, Cu, Pb, Ni, Zn, and V from water samples with the ICP-MS technique.
The concentration of each element is expressed in µg/l.
73 €
Read morePharmaceutical residues in untreated waste water samples according to Directive (EU) 2024/3019
The analysis determines the concentration of substances listed in Annex I to Directive (EU) 2024/3019 on urban wastewater treatment. Substances that can be very easily treated: Amisulprid (CAS: 71675-85-9), Carbamazepine (CAS: 298-46-4), Citalopram (CAS: 59729-33-8), Clarithromycin (CAS: 81103-11-9), Diclofenac (CAS: 15307-86-5), Hydrochlorothiazide (CAS: 58-93-5), Metoprolol (CAS: 37350-58-6), Venlafaxine (CAS: 93413-69-5). Substances that can be easily disposed of: Benzotriazole (CAS: 95-14-7), Candesartan (CAS: 139481-59-7), Irbesartan (CAS: 138402-11-6), 4-Methylbenzotriazole (CAS No 29878-31-7), 5-methyl-benzotriazole (CAS No 136-85-6), The sum of 4-Methylbenzotriazole & 5-methyl-benzotriazole can be reported if requested. This analysis is intended for untreated wastewater. We also offer an analysis with the same target analytes for treated wastewater to determine how effectively the substances are removed during the treatment process. Read more about the testing requirements imposed by the new Urban Wastewater Treatment Directive here.
Read more
Dissolved silicon in ultrapure water
The measurement determines the content of dissolved silicon in ultrapure water using UV-Vis spectroscopy (molybdenum heteropolyblue method). The silicon detection limit is 0.7 ppb. The sample must be collected in a suitable sample container designed for ultrapure water. Measurlabs can provide the required sample vessels upon request.
157 €
Read morePharmaceutical residues in treated waste water samples according to Directive (EU) 2024/3019
Analysis to determine the concentrations of organic substances (pharmaceuticals and drug precursors) listed in the revised Urban Wastewater Treatment Directive (EU) 2024/3019. The analysis includes eight substances that can be very easily treated: Amisulprid (CAS: 71675-85-9), Carbamazepine (CAS: 298-46-4), Citalopram (CAS: 59729-33-8), Clarithromycin (CAS: 81103-11-9), Diclofenac (CAS: 15307-86-5), Hydrochlorothiazide (CAS: 58-93-5), Metoprolol (CAS: 37350-58-6), Venlafaxine (CAS: 93413-69-5). And four substances that can be easily disposed of: Benzotriazole (CAS: 95-14-7), Candesartan (CAS: 139481-59-7), Irbesartan (CAS: 138402-11-6), Mixture of 4-Methylbenzotriazole (CAS No 29878-31-7) and 6-methyl-benzotriazole (CAS No 136-85-6). This method is suitable for wastewater samples with low total solids and dissolved solids content. Please check the suitability of the sample matrix with the testing expert when requesting an offer.
Read more
Elemental impurities in ultrapure water
Determination of 36 elemental impurities from ultra-pure water with ICP-MS. The measurement includes the following elements: Al, Sb, As, Ba, Be, Bi, B, Cd, Ca, Cr, Co, Cu, Ga, Ge, Au, Fe, Pb, Li, Mg, Mn, Mo, Ni, Nb, Pt, K, Ag, Na, Sr, Ta, Tl, Sn, Ti, W, V, Zn, and Zr. The sample must be collected in a suitable container designed for ultrapure water. Measurlabs can provide the required sample vessels.
396 €
Read more”Measurlabs was extremely helpful in all our requests during the preceding months. When we had high time pressure to get analytical support, they handled all our requests swiftly. Whenever we have future analytical needs we will remember their excellent service.”
Erich Seger, H.B. Fuller Deutschland GmbH
Ask for an offer
Fill in the form, and we'll reply in one business day.
Have questions or need help? Email us at info@measurlabs.com or call our sales team.