Simulated distillation of petroleum fractions according to ASTM D7169
Simulated distillation (SimDist or Simdis) according to the ASTM D7169 standard helps determine the boiling point of petroleum fractions. Sample needs to be soluble to CS2.
The method will provide a boiling point distribution of n-C9 to n-C100 (or up to 720 °C) as mass percent yields.
- Suitable sample matrices
- Samples with boiling point between n-C9 - n-C100 and sufficiently low vapour pressure to allow sampling at room temperature
- Required sample quantity
- 50 ml
- Typical turnaround time
- 3 weeks after receiving the samples
- Available quality systems
- Accredited testing laboratory
- Standard
- Method expert
Price
Price per sample (Excl. VAT):
257 €
We also charge a 97 € service fee per order.
Large batches of samples are eligible for discounts.
Questions? We're happy to help.
Questions? We're happy to help.
Business hours: Mon–Fri 9 AM – 5 PM Finnish time (EST/EEST)
Other tests we offer
Automotive diesel testing package according to EN 590 standard
EN ISO 10370, EN ISO 12156-1, EN ISO 12185, …
Standard EN 590 outlines the testing requirements and methods for diesel fuel quality testing. The following tests are included in the package: Standard Parameter Requirements EN 5165 Cetane number Min. 51 EN ISO 4264 Cetane index Min. 46 EN ISO 12185 Density at 15 °C 820 - 845 kg/m3 EN 12916 Polycyclic aromatic hydrocarbons (PAH) Max. 8 m% EN ISO 20846 Sulfur content Max. 10 mg/kg EN 16576 Manganese content Max. 2.0 mg/l EN ISO 2719 Flashpoint Min 55 °C EN ISO 10370 Carbon residue Max. 0.30 m% EN ISO 6245 Ash content Max. 0.010 m% EN ISO 12937 Water content Max. 200 mg/kg EN 12662 Total contamination Max. 24 mg/kg EN ISO 2160 Copper corrosion Class 1 EN 14078 FAME content Max. 7.0 v% EN ISO 12205 Oxidation stability Max. 25 g/m3/min. 20 h EN ISO 12156-1 Lubricity at 60 °C Max. 460 µm EN ISO 3104 Viscosity at 40 °C 2000 - 4500 mm2/s ISO 3405 Distillation characteristics E250 max 65 v%, E350 min. 85 v%, T95 360 °C EN 116 Cold filter plugging point Different grades* EN ISO 23015 Cloud point Different classes** * Temperate climates: Grade A: max. +5 °C, B: max. 0 °C, C: max. -5 °C, D: max. -10 °C, E: max. -15 °C, and F: max. -20 °C. Arctic or severe winter climates: Class 0: max. -20 °C, 1: max. -26 °C, 2: max. -32 °C, 3: max. -38 °C, and 4: max. -44 °C. ** Arctic or severe winter climates: Class 0: max. -10 °C, 1: max. -16 °C, 2: max. -22 °C, 3: max. -28 °C, and 4: max. -34 °C. For individual tests and their prices, please contact us through the form below.
2,279 €
Read moreDiesel exhaust fluid (e.g. AdBlue) testing according to ISO 22241
ISO 22241-1
Diesel exhaust fluid (DEF) is an additive used in diesel-powered vehicles to help the catalytic reduction of nitrous oxides. Thus, the use of AdBlue and other exhaustive fluids improves ambient air quality. DEF testing package according to ISO 22241:2019 includes the measurements listed below: Urea content (ISO 22241-2C), Density at 20 °C (EN ISO 12185) , Refractive index at 20 °C (ISO 22241-2C), Alkalinity as NH3 (ISO 22241-2D), Biuret (ISO 22241-2E), Aldehydes (ISO 22241-2F), Insoluble matter (ISO 22241-2G), Phosphate (ISO 22241-2H), Determination of Al, Ca, Cr, Cu, Fe, K, Mg, Na, Ni, and Zn content (ISO 22241-2I).
315 €
Read moreGasoline testing package according to EN 228 standard
EN ISO 12185, EN ISO 20846, EN ISO 2160, …
Standard EN 228 outlines the testing requirements and methods for gasoline quality testing. The following tests are included in the package: Standard Parameter Requirements EN ISO 5164 RON Min. 95 EN ISO 5163 MON Min. 85 EN 237 Lead content Max. 5 mg/l EN ISO 12185 Density at 15 °C 720–775 kg/m3 EN ISO 20846 Sulfur content Max. 10 mg/kg EN 16136 Manganese content Max. 2 mg/l EN ISO 7536 Oxidation stability Min. 360 minutes EN ISO 6246 Washed gum content Max. 5 mg/100ml EN ISO 2160 Copper corrosion Class 1 ASTM D4176 Appearance Bright and clear EN ISO 22854 Hydrocarbon composition Benzene max. 1 v%, aromatics max. 35 v%, olefins max. 18 v%, oxygenates* EN 13016-1 Vapor pressure at 37.8 °C (DVPE) Depends on volatility class** EN ISO 3405 Distillation characteristics Final boiling point max. 210 °C, distillation residue max. 2 v%, evaporated volumes*** * For gasoline with max. 3.7 m% of oxygen, allowed oxygenate contents are methanol 3 v%, ethanol 10 v%, iso-propanol 12 v%, iso-butanol 15 v%, tert-butanol 15 v%, ethers with five or more carbon atoms 22 v%, and other oxygenates 15 v%. For gasoline with max. 2.7 m% of oxygen, allowed oxygenate contents are methanol 3 v% and ethanol 5 v%. ** For volatility class A: 45–60 kPa, B: 45–70 kPa, C: 50–80 kPa, D: 60–90 kPa, E: 65–95 kPa, and F: 70–100 kPa *** Percentage evaporated at 70 °C (E70): winter 22–50 v%, summer 22–48 v%, at 100 °C (E100): 46–71 v%, and at 150 °C (E150): min. 75 v%
2,171 €
Read moreMetal screening by ICP-SFMS (semi-quantitative)
This metal screening analysis includes the semi-quantitative determination of 70 elements. The method can be used, for example, to determine the background concentrations of metals in environmental samples or to study the elemental distribution of unknown samples. Screening is also often performed to assess which metals should be analyzed by a quantitative method. The measurement is performed using a high-resolution ICP-MS technique (ICP-SFMS), which can identify very low elemental concentrations. A semi-quantitative determination of the following elements is included: Ag, Al, As, Au, B, Ba, Be, Bi, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Dy, Er, Eu, Fe, Ga, Gd, Ge, Hf, Hg, Ho, I, Ir, K, La, Lu, Mg, Mn, Mo, Na, Nb, Nd, Ni, Os, P, Pb, Pd, Pr, Pt, Rb, Re, Rh, Ru, S, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Te, Th, Ti, Tl, Tm, U, V, W, Y, Yb, Zn and Zr. However, please note that some elements may not be determinable due to matrix interference. During this semi-quantitative analysis, the instrument is calibrated for about 30 elements and the rest of the analytes are quantified using sensitivity factors for calibrated elements with similar mass and first ionization potential considering isotope abundances. Quantitative analysis is also available at an additional price. During this analysis, all elements are calibrated (excluding halogens and Os). Please ask for an offer for this service.
753 €
Read moreTotal organic fluorine (TOF) content in challenging sample materials (chemicals, oils, etc.)
ASTM D7359
Determination of the total organic fluorine (TOF) content in combustible materials by combustion ion chromatography (CIC). TOF analysis gives information about the total amount of organic fluorinated compounds. It can also be used to evaluate the presence of per- and polyfluoroalkyl substances (PFAS) in the material, even though individual PFAS compounds can't be analyzed with this method. The analysis is suitable for many different materials. Please describe the sample in detail when requesting an offer to help us prepare a quote quickly.
350–600 €
Read moreIdentification of chemical groups with FTIR (solid samples)
Qualitative identification of chemical groups in solid samples by Attenuated total reflectance Fourier-transform infrared spectroscopy (ATR-FTIR). Results will be delivered as an FTIR spectrum. In addition, a comparison to an FTIR library will be provided. The method is not quantitative, but it can be used to identify the main chemical components of the sample.
170 €
Read moreCHNOS analysis of organic materials
Determination of carbon, hydrogen, nitrogen, sulfur, and oxygen content of an organic sample. CHNS analysis (”LECO analysis”) is performed using a flash combustion method, where the sample is combusted under 25 kPa of O2 at an elevated temperature (1000 °C), followed by gas chromatography separation and detection using a thermal conductivity detector. Oxygen is analyzed by reduction on granulated carbon at 1480 °C, utilizing high-temperature thermal decomposition and conversion of oxygen into carbon monoxide before gas chromatography separation and detection with a thermal conductivity detector. The sample can be either solid or liquid, but water in the sample affects the results. In the case of aqueous samples, it is possible to dry the sample before analysis. The price includes two parallel measurements. The results are reported as wt-% of the initial sample. The ash, drying and dry loss measurements will increase the minimum required sample material need to 300 mg. The analysis gives the total carbon, hydrogen, nitrogen, sulfur, and oxygen content of the material, but it does not identify any chemical structures. The measurement can be combined with other methods, such as GC-MS, 1H, and 13C NMR, to perform substance structure identification. Possible element packages: O, CHNS, and CHNOS.
119–415 €
Read moreBiomass fraction of CO2 emissions for carbon emissions trading
ASTM D6866
Determination of the biomass fraction of CO2 emissions generated from mixed fuel incineration, as required by the EU Emissions Trading System (ETS). CO2 originating from non-fossil sources like biomass has an emission factor of zero under EU ETS and is therefore not counted towards carbon emissions. This means that the biomass fraction of mixed fuels, such as municipal waste or solid recovered fuel (SRF), must be determined to calculate reportable emissions accurately. In this analysis, the proportion of biogenic carbon dioxide in total emitted CO2 from the incineration process is measured using the radiocarbon (14C) method. The measurement is based on the ASTM D6866 standard. This standard is equally rigorous and based on the same methodology as EN ISO 13833, which is mentioned in Commission Implementing Regulation (EU) 2018/2066 on the monitoring and reporting of greenhouse gas emissions. Testing is relevant for industrial plants that use mixed fuels and participate in emissions trading, as well as for municipal waste incineration (MWI) plants, which have been required to monitor and report emissions according to EU ETS since the beginning of 2024.
430 €
Read moreRaman spectroscopy - gas samples
Analysis of gaseous samples using Raman spectroscopy.
541–797 €
Read moreBiobased carbon content according to ISO 16620
ISO 16620
The biobased carbon content is either reported as a fraction of the total organic carbon (TOC) or total carbon (TC). The price is for non-volatile samples. If your sample is volatile, please discuss the suitability of your sample type with our experts. Please also note that we cannot accept samples that contain artificial carbon-12, carbon-13, or carbon-14 isotopes because they will cause damage to the equipment.
686 €
Read more”Measurlabs was extremely helpful in all our requests during the preceding months. When we had high time pressure to get analytical support, they handled all our requests swiftly. Whenever we have future analytical needs we will remember their excellent service.”
Erich Seger, H.B. Fuller Deutschland GmbH
Ask for an offer
Fill in the form, and we'll reply in one business day.
Have questions or need help? Email us at info@measurlabs.com or call our sales team.