Automotive diesel testing package according to EN 590 standard
Standard EN 590 outlines the testing requirements and methods for diesel fuel quality testing. The following tests are included in the package:
Standard | Parameter | Requirements |
---|---|---|
EN 5165 | Cetane number | Min. 51 |
EN ISO 4264 | Cetane index | Min. 46 |
EN ISO 12185 | Density at 15 °C | 820 - 845 kg/m3 |
EN 12916 | Max. 8 m% | |
EN ISO 20846 | Sulfur content | Max. 10 mg/kg |
EN 16576 | Manganese content | Max. 2.0 mg/l |
EN ISO 2719 | Flashpoint | Min 55 °C |
EN ISO 10370 | Carbon residue | Max. 0.30 m% |
EN ISO 6245 | Ash content | Max. 0.010 m% |
EN ISO 12937 | Water content | Max. 200 mg/kg |
EN 12662 | Total contamination | Max. 24 mg/kg |
EN ISO 2160 | Copper corrosion | Class 1 |
EN 14078 | FAME content | Max. 7.0 v% |
EN ISO 12205 | Oxidation stability | Max. 25 g/m3/min. 20 h |
EN ISO 12156-1 | Lubricity at 60 °C | Max. 460 µm |
EN ISO 3104 | Viscosity at 40 °C | 2000 - 4500 mm2/s |
ISO 3405 | Distillation characteristics | E250 max 65 v%, E350 min. 85 v%, T95 360 °C |
EN 116 | Cold filter plugging point | Different grades* |
EN ISO 23015 | Cloud point | Different classes** |
* Temperate climates: Grade A: max. +5 °C, B: max. 0 °C, C: max. -5 °C, D: max. -10 °C, E: max. -15 °C, and F: max. -20 °C. Arctic or severe winter climates: Class 0: max. -20 °C, 1: max. -26 °C, 2: max. -32 °C, 3: max. -38 °C, and 4: max. -44 °C.
** Arctic or severe winter climates: Class 0: max. -10 °C, 1: max. -16 °C, 2: max. -22 °C, 3: max. -28 °C, and 4: max. -34 °C.
For individual tests and their prices, please contact us through the form below.
- Suitable sample matrices
- Automotive diesel
- Required sample quantity
- 4 liters
- Typical turnaround time
- 4 weeks after receiving the samples
- Available quality systems
- Measurlabs validated method
- Standard
- Method expert
Questions? We're happy to help.
Questions? We're happy to help.
Ask for an offer
Fill in the form, and we'll reply in one business day.
Have questions or need help? Email us at info@measurlabs.com or call our sales team.