Content of volatile matter in silicone elastomers
Accredited laboratory analysis for determining the amount of volatile organic matter in silicone used in food contact materials or childcare articles.
Testing can be conducted according to the following methods and references:
Applicable materials | Drying phase | Treatment phase | Compliance limit | Test method | Reference |
---|---|---|---|---|---|
General food contact materials made from silicone elastomer | 1 h / 100 °C | 4 h / 200 °C | ≤ 0.5 % | Bestimmung von flüchtigen Verbindungen in Bedarfsgegenständen aus Silikon (version 02, 09/2023) | BfR XV. Silicones (as of 01.08.2024) |
Childcare articles intended for drinking | 1 h / 100 °C | 4 h / 200 °C | ≤ 0.5 % | EN 14350, art 8.4.2 | EN 14350 |
Childcare articles intended for feeding | 1 h / 100 °C | 4 h / 200 °C | ≤ 0.5 % | EN 14372, art. 6.3.3 | EN 14372 |
- Suitable sample matrices
- Silicones, childcare articles
- Required sample quantity
- 50 g
- Typical turnaround time
- 4 weeks after receiving the samples
- Available quality systems
- Accredited test method
- Standard
- Method expert
Price
We also charge a 97 € service fee per order.
Large batches of samples are eligible for discounts.